HOMEOWNER TROUBLESHOOTING GUIDE

Heat Pump Not Heating? What to Check Before You Call

Heat pump blowing cold air in Indiana or Westmoreland County, PA? Tell defrost from a real failure, when to use emergency heat and when to call HVAC.

Call Now for Repair Help(724) 300-2927

Referral service. Calls may be recorded and may be routed to an independent local service provider.

Homeowner education · Public references listed below · Read our editorial standards

Heat pump blowing cold air or iced over? Call now to be connected with a local heat pump and HVAC pro.

Referral service. Calls may be recorded and may be routed to an independent local service provider.

QUICK ANSWER

Where to start

If your heat pump is not heating, first check that the thermostat is set to Heat (not Cool or Fan), the set point is above room temperature, the filter is not clogged and the outdoor unit's breaker has not tripped. Steam and a stopped outdoor fan for a few minutes is usually a normal defrost cycle, not a breakdown. If the outdoor unit is frozen solid, will not run, makes grinding or banging noises, or the house keeps losing heat, switch to Emergency Heat only as a stopgap and call to be connected with a local heat pump technician.

Key points

  • Steam from the outdoor unit and a fan that stops for 5 to 15 minutes is usually a normal defrost cycle, not smoke or a failure.
  • Heat pump air feels cooler than furnace air even when everything is working, so judge by whether the house holds temperature.
  • A thin layer of frost is normal; a unit encased in solid ice that does not clear after a defrost cycle needs service.
  • Emergency Heat shuts the heat pump off and runs only backup heat. Use it as a temporary fix when the outdoor unit has failed, not as a cold-weather setting.
  • If the breaker trips twice, you smell burning, or the house keeps getting colder in a cold snap, stop resetting and call.

Match what your heat pump is doing to the safer next step

These observations help describe the issue, not diagnose it. Stop if conditions become unsafe.

What you seeSafer response
Steam from the outdoor unit and its fan stopped for a few minutesUsually a normal defrost cycle. Wait 15 minutes before changing any setting.
Outdoor unit encased in ice that does not clear after defrostDo not chip the ice. Switch to Emergency Heat and call for heat pump service.
Outdoor unit silent and its breaker trippedReset it once from a dry spot. If it trips again, leave it off and call.
House keeps getting colder and Aux or EM heat runs nonstopProtect pipes from freezing, keep backup heat on and arrange a diagnosis.

First five minutes: the quick checks that fix many no-heat calls

Start at the thermostat. Make sure the mode is Heat or Auto, not Cool, Off or Fan only, and that the set point is a few degrees above the current room temperature. Replace the batteries if the screen is blank or dim. After a power outage, some thermostats come back on in a different mode or schedule, so check that too.

Next, look at the air filter at the indoor air handler or return grille. A filter packed with dust starves the system of airflow, and a heat pump with poor airflow can deliver weak, lukewarm air or shut itself down on a safety limit. Replace it with the size printed on the frame, with the airflow arrow pointing toward the unit.

Then check power. A heat pump has two parts: the outdoor unit and the indoor air handler or furnace. Each usually has its own breaker in the main panel, and the outdoor unit also has a disconnect box on the wall next to it. If a breaker has tripped, reset it once from a dry spot. If it trips again, leave it off and call. Repeated tripping points to an electrical or compressor fault, and our breaker guide explains why resetting again and again is risky.

Finally, give the system time. Many heat pumps and thermostats have built-in delays of a few minutes before the compressor restarts. Changing the setting over and over can keep resetting that timer and make it look as if nothing is happening.

Defrost cycle or real problem? Steam, noise and a stopped fan

In cold, damp weather, frost forms on the outdoor coil. To clear it, the heat pump briefly reverses itself and sends heat to the outdoor coil. During this defrost cycle the outdoor fan stops, you may hear a whoosh when the valve switches, and a cloud of steam can rise from the unit. Lennox says the whole process usually takes 5 to 15 minutes, and that defrosting even when it is in the 40s outside is not unusual.

While it defrosts, the air from your vents can feel cool for a few minutes, or the thermostat may show Aux heat while backup heat covers the gap. That is the system protecting itself, not a breakdown.

It becomes a problem when the defrost does not work. Lennox advises having repeated or very long defrost cycles checked by a professional. Other warning signs are ice that keeps building until the coil or the whole unit is encased, ice on the top of the unit or fan blades, a fan that does not restart, and grinding or banging from the outdoor unit.

Do not chip or pry ice off the coil with a shovel, screwdriver or ice pick. The thin aluminum fins and refrigerant tubing are easy to puncture, and a refrigerant leak turns a service call into a much larger repair. Do not pour boiling water on it either. If it is frozen solid, switch to Emergency Heat and call.

Why heat pump air feels cool, and when it really is too cold

Many homeowners in Indiana County and Westmoreland County grew up with gas or oil furnaces that blow very hot air. A heat pump moves heat from outdoor air into the house and delivers it at a lower temperature over longer run times. Air that feels lukewarm on your hand is normal if the house is holding the temperature you set.

Cold weather makes the gap bigger. EPRI notes that an air-source heat pump's heating capacity and efficiency fall as the outdoor temperature drops, which is why most systems are installed with backup heat, usually electric heat strips or, in a dual-fuel setup, a gas, oil or propane furnace. The U.S. Department of Energy says newer cold-climate heat pumps can keep heating in much colder regions, but an older standard model in a drafty house may simply run nonstop on the coldest nights.

The real test is the trend. If the house keeps dropping several degrees below the set point and does not recover even in milder weather, if the system runs on backup heat all the time, or if the air from the vents is cold for long stretches outside a defrost cycle, something is wrong. Low refrigerant from a leak, a failed reversing valve, a bad defrost control, a failed compressor or capacitor, or backup heat that is not working are common findings, and all of them need a technician with gauges and meters.

Heat pump blowing cold air or iced over? Call now to be connected with a local heat pump and HVAC pro.

Referral service. Calls may be recorded and may be routed to an independent local service provider.

Aux heat vs Emergency Heat: which setting to use

Aux or Auxiliary heat turns on automatically. The thermostat adds backup heat during defrost, on very cold days, and when you raise the temperature by several degrees at once. Seeing Aux for short periods is normal. You do not need to do anything.

Emergency Heat, often labeled EM or EMER, is a manual setting. Lennox explains that it shuts off the heat pump completely and runs only the backup source. Use it when the outdoor unit has clearly failed, is frozen solid or damaged by ice or storm debris, or when a technician tells you to. Electric heat strips use a lot more electricity than the heat pump, so expect a higher bill while it is on and switch back to normal Heat after the repair.

If the thermostat is showing EM and nobody knows why, set it back to Heat and watch whether the outdoor unit starts. If Emergency Heat does not warm the house either, the backup heat or the indoor unit may have a problem too, and the call is more urgent.

Large setbacks can also bring on backup heat. Turning the thermostat down to 60 at night and back up to 70 in the morning can make many thermostats run the heat strips to catch up. Smaller, steady changes are usually easier on the bill.

Keep the house safe while you wait in a cold snap

Losing heat in a Western Pennsylvania cold snap can quickly become a frozen pipe problem, especially in older homes in Indiana, Blairsville, Homer City, Greensburg, Latrobe, Jeannette and Murrysville with plumbing along outside walls or in crawl spaces. Open sink cabinet doors on outside walls, keep interior doors open, and let a faucet on an outside wall drip slightly.

Use only electric space heaters made for indoor use, plug them directly into a wall outlet, and keep them three feet from anything that can burn. Never heat the house with a gas oven, grill, camp stove or a generator. Generators belong outdoors, far from windows, doors and vents.

If you have a dual-fuel system with a gas, oil or propane furnace as backup, working carbon monoxide alarms matter. If a CO alarm sounds, get everyone outside and call 911 first. Keep snow cleared from around the outdoor unit and from any furnace vent pipes on the side of the house after a storm.

What the symptoms may tell you

Thermostat is on Heat, the set point is above room temperature, and only cool air comes out for long stretches outside a defrost cycle.

The outdoor unit is silent, its fan will not start, or it hums, grinds or bangs.

Ice keeps building on the outdoor coil or covers the whole unit and does not clear after a defrost cycle.

The breaker for the outdoor unit or air handler trips again after one reset, or there is a burning smell.

The thermostat shows Aux or EM heat all the time and the electric bill has jumped.

Homeowner checklist

  • Set the thermostat to Heat, raise the set point a few degrees and replace weak batteries.
  • Replace a clogged air filter and make sure supply and return vents are open.
  • Check the breakers for the outdoor unit and air handler; reset a tripped breaker only once.
  • Wait 15 minutes to rule out a normal defrost cycle before deciding the unit has failed.
  • Clear snow, leaves and debris from around the outdoor unit by hand or with a broom; never chip ice off the coil.
  • If the outdoor unit has failed or is frozen solid, switch to Emergency Heat and call for service.
  • Write down the model number, any error code on the thermostat or unit, and what you saw and heard.

Safety first

Turn power off at the disconnect or breaker before clearing debris near the outdoor unit, and never open electrical panels, touch refrigerant lines or chip ice off the coil. If a breaker trips more than once, you smell burning or see scorching, leave it off and call. With a dual-fuel or fuel-burning backup, a carbon monoxide alarm means get out and call 911 first. Never heat a home with an oven, grill or generator.

When to involve a professional

Call a qualified HVAC technician who services heat pumps when the house will not hold temperature, the outdoor unit will not run or stays iced, the system runs only on backup heat, a breaker keeps tripping, or you hear grinding or banging. Ask for a diagnosis of defrost controls, refrigerant charge, reversing valve, compressor and backup heat. Confirm insurance, diagnostic fees, timing and refrigerant handling certification directly with the provider you choose.

Questions to ask before agreeing to work

  1. What exactly failed, and how did you test it: defrost control, reversing valve, capacitor, compressor or refrigerant charge?
  2. If refrigerant is low, where is the leak and will you repair it, not just add refrigerant?
  3. Is the backup heat working, and are the thermostat's Aux and Emergency Heat settings set up correctly for this system?

Frequently asked questions

Why is my heat pump blowing cold air?

The most common reasons are a normal defrost cycle (a few minutes of cool air while steam rises outside), a thermostat set to Cool or Fan, a clogged filter, or a tripped breaker on the outdoor unit. If cold air continues for long stretches, the unit is iced over, or the house keeps getting colder, a technician should check the defrost controls, refrigerant charge, reversing valve and backup heat.

Is it normal for my heat pump to steam in winter?

Yes. Steam rising from the outdoor unit while its fan is stopped is usually a defrost cycle melting frost off the coil. Lennox says a cycle typically lasts 5 to 15 minutes. Smoke, a burning smell, or steam with grinding noises is not normal; turn the unit off at the thermostat and call.

Should I switch to Emergency Heat when it is very cold outside?

Usually not. Emergency Heat turns the heat pump off and runs only the backup heat, which costs more to run. Aux heat already turns on automatically in very cold weather. Use Emergency Heat when the outdoor unit has failed, is frozen solid or damaged, or a technician tells you to, and switch back after the repair.

My heat pump is covered in ice. What should I do?

Light frost that clears after a defrost cycle is normal. If ice covers the coil or the whole unit and does not clear, switch the thermostat to Emergency Heat, check that gutters or roof runoff are not dripping onto the unit, and call for service. Do not chip ice off with tools or pour boiling water on it.

Can you connect me with a heat pump repair pro in Indiana, Greensburg or Murrysville?

Yes. Our referral service covers Indiana County and Westmoreland County, including Indiana, Blairsville, Greensburg, Latrobe and Murrysville. Calls may be recorded and may be routed to an independent local service provider, who confirms availability, timing and price with you.