Boiler Not Working? No Heat From Radiators: What to Check First

Boiler not working or radiators cold in Indiana or Westmoreland County, PA? Safe checks for pressure, water level and resets, and when to call for repair.

Call Now for Repair Help(724) 300-2927

Referral service. Calls may be recorded and may be routed to an independent local service provider.

Homeowner education · Public references listed below · Read our editorial standards

Boiler out and the house getting cold? Call to be connected with a local boiler and heating repair pro tonight.

Referral service. Calls may be recorded and may be routed to an independent local service provider.

QUICK ANSWER

Where to start

If your boiler is not working, first make sure nobody is in danger: if you smell gas, see water spraying from the relief valve or a carbon monoxide alarm sounds, leave and call 911 or your gas utility from outside. If it is safe, check the thermostat, the boiler power switch and breaker, and the gauge. On a hot-water boiler, Weil-McLain says the pressure should not go above 24 psi, and systems are often filled to about 12 psi cold. On a steam boiler, the water in the sight glass should sit about halfway up. Press a reset button once at most. If the boiler will not run, keeps locking out, leaks or the pressure is wrong, turn it off and call a heating technician.

Key points

  • Safety first: gas smell, a carbon monoxide alarm, or water or steam blowing from the relief valve means leave the boiler alone and call for help.
  • Most no-heat calls start with simple checks: thermostat set to Heat, boiler power switch on, breaker not tripped and fuel (gas, oil or propane) available.
  • Hot-water boilers: Weil-McLain says the gauge should not read above 24 psi; the relief valve opens at 30 psi, and many systems are filled to about 12 psi cold.
  • Steam boilers: the normal waterline is about halfway up the sight glass. An empty glass means the low-water cutoff has likely shut the burner off for safety.
  • Never add cold water to a hot boiler and never cap or plug a dripping relief valve. HomeGuide lists most boiler repairs at $150 to $700.

Match what the boiler is doing to the safe next step

These observations help describe the issue, not diagnose it. Stop if conditions become unsafe.

What you see at the boilerSafe next step
Silent boiler, no burner or pump, thermostat calling for heatCheck the thermostat batteries and setting, the boiler service switch, the breaker and the fuel supply, then call if it still will not start.
Hot-water gauge near zero, or radiators cold at the top and gurglingThe system has likely lost water. Write down the reading, look for leaks and call; do not add cold water to a hot boiler.
Steam sight glass empty or water level dropping fastThe low-water cutoff has likely stopped the burner. Let the boiler cool and call a technician to find where the water is going.
Gauge near 30 psi, relief valve spraying, gas smell or CO alarmTurn the boiler off or leave the house as needed and call now; never cap the relief valve or stay inside with a gas smell.

First, is it a boiler emergency?

Many older homes in Indiana County and Westmoreland County heat with a boiler: a cast iron unit in the basement that sends hot water or steam to radiators or baseboard heaters. When it stops on a cold November night, the house loses heat slowly, but some problems are dangerous and should not be troubleshot at all.

Leave the house and call from outside if you smell gas (a rotten-egg smell), if a carbon monoxide alarm is sounding, or if you see smoke or scorch marks around the boiler. Weil-McLain's owner manual says that if you smell gas, do not try to light any appliance, do not touch any electrical switch and do not use a phone inside the building; call your gas supplier from a neighbor's phone, or the fire department if you cannot reach them.

Also stop and call if water or steam is blowing out of the relief valve pipe, the pressure gauge reads at or near 30 psi on a hot-water boiler, water is pooling around the boiler, or the boiler or its controls have been under water from a flooded basement. Weil-McLain says not to use a boiler if any part of it has been under water until a qualified technician has inspected it.

Hot-water boiler or steam boiler? How to tell

The checks are different, so figure out which one you have. A hot-water (hydronic) boiler has a round pressure and temperature gauge, an expansion tank (often a small gray or blue tank on the piping, or an older steel tank near the ceiling), and a circulator pump. It heats baseboards or radiators with water, and the radiators get warm all over.

A steam boiler has a glass tube on its side, called a gauge glass or sight glass, that shows the water level inside, plus a low-pressure gauge that reads in single digits. Radiators may have small air vents that hiss when the heat comes up. Boilers and radiators show up most in older housing; in Jeannette, for example, Census ACS 2020-2024 data put the median year built at 1952, and many homes in Indiana, Greensburg and Latrobe are of a similar age.

What to check right now, step by step

1. Check the thermostat. Make sure it is set to Heat and a few degrees above room temperature, and replace its batteries if the screen is blank or dim.

2. Check power. Boilers have a service switch that looks like a light switch, usually on the boiler, at the basement stairs or on a nearby wall. Make sure it is on, and check the breaker or fuse for the boiler circuit. If the breaker trips again right away, leave it off and call.

3. Check fuel. Is the gas on at the meter and are other gas appliances working? On oil or propane, check the tank gauge. An empty oil or propane tank will stop the boiler, and it can take a delivery and a burner restart to get heat back.

4. Read the gauge (hot-water boilers). Weil-McLain says the pressure should not exceed 24 psi, and its installation manual says systems are typically sized for about 12 psi when the water is cold. A reading near zero means the system has lost water; a reading near 30 psi means the relief valve is about to open. Write down the number before you call.

5. Check the water level (steam boilers). Weil-McLain says the normal waterline on a steam boiler is halfway up the gauge glass. If the glass is empty, the low-water cutoff has probably shut the burner off. Do not add cold water to a hot boiler: Weil-McLain warns the thermal shock can crack the sections. Let it cool, or call.

6. Look for a reset or lockout light. Many boilers and oil burners have a reset button or a flashing light. Press reset once only. If the boiler locks out again, stop and call: a repeat lockout is a safety control telling you something is wrong, and pressing reset over and over does not fix it.

7. If only some radiators are cold, it may be air or low pressure. Weil-McLain lists air in the system and low system pressure as common causes of radiators or baseboards that do not heat or are noisy. Weil-McLain's fix is to bleed air through the radiator or baseboard vents and fill to the correct pressure; letting air out can drop the pressure, so check the gauge afterward.

Boiler out and the house getting cold? Call to be connected with a local boiler and heating repair pro tonight.

Referral service. Calls may be recorded and may be routed to an independent local service provider.

Common reasons a boiler stops heating

Low water or low pressure: a leak, a dripping relief valve, a steam vent spitting water or a fill valve that is not keeping up. Weil-McLain says leaks must be repaired at once, because constant fresh makeup water brings in minerals and oxygen that shorten boiler life.

High pressure and a dripping relief valve: on hot-water boilers this usually points to a waterlogged or undersized expansion tank or a fill valve problem. Weil-McLain lists a flooded or undersized expansion tank as the common cause of frequent water release through the relief valve.

No ignition or flame: a failed igniter, flame sensor, pilot, gas valve or oil burner part. HomeGuide notes that common gas boiler repairs include igniters, gas valves, circulating pumps and loose wiring.

Circulator pump or zone valve failure: the boiler gets hot but the water does not move, so one zone or the whole house stays cold. HomeGuide says a broken circulating pump will not send hot water through the heating pipes.

Blocked venting: snow, ice or a bird nest at the vent or chimney. Weil-McLain says many boilers shut themselves down when the vent or air intake is blocked, and that you can remove an easily reached blockage, after which the boiler should try to restart within an hour. Anything else needs a technician.

Keep the house safe while you wait

Frozen pipes are the next problem when a boiler is out. The American Red Cross recommends keeping the heat no lower than 55 degrees F when it is very cold, opening sink cabinets on outside walls and letting a faucet drip on exposed pipes. Weil-McLain also warns that in severe cold a boiler failure or power outage can lead to frozen plumbing and water damage within hours, especially in a vacant home or rental.

Use only indoor-rated electric space heaters, plugged straight into a wall outlet and kept at least three feet from anything that can burn. Never heat the house with a gas oven, grill, camp heater or generator. If your boiler also makes your hot water, expect no hot water until it is fixed.

If you rent in Indiana, Homer City, Greensburg or Jeannette, tell your landlord or property manager in writing right away and take a photo of the gauge and any leak.

What boiler repair can cost

There is no local price list, and this website does not set prices. As national reference points, HomeGuide lists an average boiler repair at $150 to $700, a service call or call-out charge at $75 to $200, hourly service at $75 to $150, and emergency hourly service at $140 to $210.

HomeGuide's part ranges include a circulating pump at $300 to $1,100, a zone valve at $100 to $500, an expansion tank at $200 to $800, an igniter at $100 to $400 and a gas valve at $200 to $900. Oil boiler repairs run $150 to $500 on average. Ask for the service call and after-hours rate before the technician comes out, and get the repair price in writing before parts are replaced.

What the symptoms may tell you

The thermostat is calling for heat but the boiler is silent, with no burner sound and no pump running.

The hot-water pressure gauge reads near zero, or climbs toward 30 psi and the relief valve drips.

The steam sight glass is empty or the water level keeps dropping between fills.

The boiler runs but some radiators or baseboards stay cold, gurgle or bang.

A reset button or lockout light keeps tripping, or there is soot or an oily smell at an oil burner.

Homeowner checklist

  • Gas smell, CO alarm, smoke or water spraying from the relief valve: get out and call 911 or the gas utility from outside.
  • Set the thermostat to Heat a few degrees above room temperature and check its batteries.
  • Confirm the boiler service switch is on and the breaker is not tripped.
  • Check fuel: gas meter on, or oil or propane tank not empty.
  • Hot-water boiler: read and write down the pressure gauge (should not exceed 24 psi).
  • Steam boiler: check that water shows about halfway up the gauge glass; never add cold water to a hot boiler.
  • Press a reset button once at most, then call if it locks out again.

Safety first

If you smell gas, a carbon monoxide alarm sounds, or you see smoke, leave the house and call 911 or your gas utility from outside without touching light switches. Never cap, plug or tighten a dripping relief valve, never add cold water to a hot boiler, never bypass a low-water cutoff or limit control, and never run a boiler that has been under water. While the heat is off, never heat the home with a gas oven, grill or generator.

When to involve a professional

Call a qualified boiler or heating technician when the boiler will not fire after basic checks, locks out more than once, loses water or pressure, shows pressure near 30 psi, leaks, or leaves zones cold. Have the boiler model number, fuel type, the gauge reading or sight-glass level and any lockout light pattern ready. Ask how the visit is priced, whether the diagnostic charge is credited to the repair, and what the after-hours rate is. Prices, availability and arrival times are set by the independent provider, not by this website.

Questions to ask before agreeing to work

  1. What failed (igniter, gas valve, pump, zone valve, expansion tank, low-water cutoff), and how did you confirm it?
  2. Is the boiler safe to run tonight, and what has to be fixed first?
  3. What is your service call or after-hours charge, and does the quote include parts and labor?

Frequently asked questions

Why is my boiler not turning on?

The most common reasons are simple: the thermostat is not calling for heat, the boiler service switch or breaker is off, or the fuel is out. After that, a safety control may have shut it down, such as a low-water cutoff on a steam boiler, a blocked vent switch or a flame lockout. If the boiler still will not run after you check power, fuel and the thermostat, call a technician.

What should the pressure be on my hot-water boiler?

Weil-McLain says the gauge on a residential hot-water boiler should not read above 24 psi, and its installation manual says systems are typically filled to about 12 psi cold. The relief valve opens at 30 psi. The right number for your home depends on the system, so ask your technician.

Why is my boiler on but the radiators are cold?

Weil-McLain lists air in the system and low system pressure as common causes of radiators or baseboards that do not heat. A failed circulator pump or zone valve can also keep hot water from moving. If bleeding the radiators does not help, or the pressure keeps dropping, call for service.

Is a dripping boiler relief valve an emergency?

A valve that weeps now and then needs a service call soon. Water or steam blowing out, or a gauge reading near 30 psi, means turn the boiler off and call now. Never cap or plug the relief valve: it is the safety device that keeps the boiler from building dangerous pressure.

Can you connect me with a boiler repair pro in Indiana, Greensburg or Latrobe?

Yes. Our referral service covers Indiana County and Westmoreland County, including Indiana, Blairsville, Homer City, Greensburg, Latrobe, Jeannette, Ligonier, Mt Pleasant and Murrysville. Calls may be recorded and may be routed to an independent local service provider, who confirms availability, timing and price with you.